ST500DM002报No HOST FIS-ReadyStatusFlags 0002A185错误修复
发布时间:2015-9-27 11:53:29 来源:
无锡佳萱新科技
希捷500G型号ST500DM002通电长忙无法输入指令,pc3000-express设备进入指令显示如下:
Boot 0x10M Spin Up RECOV Servo Op=0100 Resp=0005[0x00000000][0x0000B67C][0x0000BA10] Trans.
Rst 0x10M MC Internal LPC Process Spin Up (P) SATA Reset
通过短接显示
RTL exceeded Starting LBA of RW Request=00132332 Length=00000010 ProcessRWError -Read- at LBA 00132332 Sense Code=43110081 Starting LBA of RW Request=00132332 Length=00000010 ProcessRWError -Read- at LBA 00132333 Sense Code=43110081 RTL exceeded No HOST FIS-ReadyStatusFlags 0002A185 ASCII Diag mode
F3 T> F3 T>m0,6,2,,,,,22 Max Wr Retries = 00, Max Rd Retries = 00, Max ECC T-Level = 1C, Max Certify Rewrite Retries = 0A8F
(DOS) Requesting File Save
User Partition Format Successful - Elapsed Time 0 mins 00 secs Zone re-format was skipped. F3 T>
断电后就绪长忙修复后成功恢复客户数据资料。 |